Talab Kashash Murtazaa; saad sami farhan
Abstract
Abstract This research has studied the Effect of Lifted Liquid Density on the Function of Air Lift Pump which consisted of a suction pipe and mixing chamber with diameter [ ( 0.0635,0.0635 ...
Read More ...
Abstract This research has studied the Effect of Lifted Liquid Density on the Function of Air Lift Pump which consisted of a suction pipe and mixing chamber with diameter [ ( 0.0635,0.0635 ) m ] , length [ ( 0.3,0.3 ) m ] and a lifting pipe of diameter ( 0.0317 m . ) length ( 2m ) . An empirical practical study have implemented to show the Effect of density for the liquid being lifted , on the pump Function throughout using two kinds of liquids ( water , Kerosene ) , at submergence ratio of ( 0.2,0.3,0.4,0.5 ) and different compressed air flow rates , with a constant temperature . When entering the mixing chamber for both supplied air and used liquid at ( 25 ° C ) . The practical results have showed an increasing of liquid pumping rate by increasing air flow rate until it reaches max . value then it will descent by increasing compressed air flow rate . We can also notice increasing of pumping rate by decreasing the used liquid density at submergence ratios and air flow rates listed in the research .